Bild


Zusatzmenue:


The future belongs to those who are willing to act in the present.

Hauptmenue:

Tools:

Untermenue:

Seiteninhalt:

JenaStereo

The software suite JenaStereo offers fast and stable raw data processing and an interface to SOCET-SET. Through its flexibility the customer can integrate its own modules into the workflow.

 

As a standalone solution the Module ASM is available for JAS raw data read-out and re-formatting, radiometric and geometric correction, boresight correction

  • geometric pre-correction to quasi epipolar images
  • archiving of intermediate result in Jena Stereo and SOCET SET format
  • stand alone process control

 

The main features of the JenaStereo modules are as follows:

  • CORE
    - process control
    - batch management
    - standard file in- and output
    - conversion of formats
    - transformation between map projections and image co-ordinates
    - evaluation of log and quality files
  • ASM Advanced Sensor Model
    - JAS raw data read-out and re-formatting
    - radiometric and geometric calibration correction
    - boresight correction
    - time adjustment
    - geometric pre-correction to quasi epipolar images
    - archiving of intermediate result in JenaStereo and SOCET SET format
    - stand alone process control
  • APT Adjusted Point Triangulation (using BINGO)
    - block definition
    - bundle adjustment
    - statistical model implementation
    - point measurements
    - quality reporting
  • ATE Automatic Terrain Extraction
    - automatic correlation
    - automatic quality control
    - automatic generation of TIN, GRID and raster DEM data
  • ORM Ortho Rectification and Mosaic
    - simultaneous rectification of all JAS channels
    - optimised re-sampling procedures
    - sharpening of colour images with high resolution panchromatic channel including colour calibration
    - free selection of the target co-ordinate system
    - orthophoto map sheet generation
    - contour controlling of seams using shape files
    - linear and histogram controlled radiometric correction
    - geometric correction controlled by shape file or correlation

 

Minimum system requirements

JenaStereo runs on Personal Computers with Linux or Windows.

 

Operating system:

  • Linux (Kernel 2.4 or greater)
  • Windows 2000 (Service Pack 5)
  • Windows XP

 

CPU:

  • AMD Athlon 2000 or Intel Pentium 2000 or faster

 

RAM:

  • 1 GB or more

 

Harddisk:

  • Approximately 250 MB are needed for the program
  • Swap file of 1 GB or greater
  • Additional space is needed for the data

 

Scheduled release date:

  • Modules CORE and ASM: in May 2006
  • All other modules: September 2006